Cat6a network patch cable is the cost-effective solution for indoor data center applications, supporting up to 10GBase-T and 550MHz within 100 meters of cable. And it is fully backward compatible with all the previous categories. The FS cat6a patch cables conductor apply Pure Bare Copper with high electrical conductivity and low signal transmission attenuation. The shielded patch cord provides superior alien crosstalk (AXT) suppression and protects critical data from electromagnetic and radio frequency interference (EMI/RFI). The sheath material is new environmentally friendly material PVC CM, which is durable, flame-retardant, resistant to bending. Stranded copper patch cable can be used with a longer flex-life. Tested and verified to meet Cat6a component requirements for ANSI/TIA-568.2-D and ISO/IEC 11801 standards. The cable supports PoE to save you the expense and effort of powering PoE devices individually. You can also install PoE devices in locations distant from power outlets, such as high on walls, ceilings or poles. Cat6a cable uses eight-core four-pair precision twisted pairing technology and passes the Fluke test, which ensures that it can provide stable high-speed network connection and ensure the accuracy and reliability of data transmission.
Cat6a 26AWG Snagless Shielded (S/FTP) PVC CM Ethernet Network Patch Cable, 24Pcs/pack
Cat6a network patch cable is the cost-effective solution for indoor data center applications, supporting up to 10GBase-T and 550MHz within 100 meters of cable.
США $81.00
- Используйте высококачественное сырье
- Быстрая доставка по умолчанию DHL или Fedex
- Возврат и обмен в течение 60 дней без проблем
- Профессиональное обслуживание клиентов
Cat6a Snagless Shielded (S/FTP) Ethernet Network Patch Cable, 26AWG, 10GBase-T
Specifications
Cable Type
Cat6a Snagless
Shielding Type
Shielded (S/FTP)
Cable Jacket
PVC CM (Round)
Length
0.5m (Including Plugs)
Conductor Material
>99.95% Oxygen-free Copper
Conductor Type
Stranded
Data Rate Support
10GBase-T
Maximum (Tested) Frequency
550MHz
Gauge (AWG)
26 (7/0.16mm)
Cable Outer Diameter (mm)
6.2 ± 0.3
Max Transmission Distance
100m
Twisted Pairs
4 Pairs
Wire Scheme
T568B, Straight
Standard
ISO/IEC 11801, ANSI/TIA-568.2-D
Plug Type
8 Position
Support FSWireNet
No
Operating Temperature
-20 to +75°C (-4 to 167°F)
Installation Temperature
-10 to +50°C (14 to 122°F)
Сопутствующие товары
Сетевой патч-кабель Ethernet 10 м Cat5e неэкранированный (U/UTP) PVC, черный
Сетевой патч-кабель Ethernet 2m Cat5e Snagless Unshielded(U/UTP)LSZH, черный
90 градусов Cat6 26AWG Snagless неэкранированный (U/UTP) ПВХ CM Ethernet сетевой патч-кабель, RJ45 правый угол вниз мужчины к RJ45 мужчины
90 градусов Cat6 26AWG Snagless неэкранированный (U/UTP) ПВХ CM Ethernet сетевой патч-кабель, RJ45 правый угол UP мужчины к RJ45 мужчины
Активный кабель USB 3.0 (5 Гбит/с) USB-A - USB-B - M/M - 5 м/10 м - TAA
Кабели Cat5e
Кабели Cat6
Кабели Cat6a
Кабели Cat8
Объемные кабели Ethernet
Разъемы и гнезда
OS2 Одномодовый симплекс
OS2 Одномодовый дуплекс
Многомодовый OM5
Многомодовый OM4
Многомодовый OM3
Многомодовый OM2
Кабели MTP/MPO
Оптоволоконная связь
Кабели DisplayPort
Кабели Mini DisplayPort
Кабели HDMI
Кабели HDMI Mini/Micro
Кабели DVI
Кабели VGA
Аудио кабели
Кабели Thunderbolt
Кабели USB-C
Кабели USB 3.0
Силовые кабели
Кабели SATA
Последовательные кабели