Cat6 UTP patch cable features 24AWG unshielded twisted pair stranded pure bare copper cable with a high-performance modular plug at each end. Snagless design protects the locking clips on the RJ45 connectors from being damaged or snapped off during installation. The flexible strain relief boot provides easy access to high-density applications. PVC (CM) jacket meets UL flame test standards.
It exceeds the performance of the Cat6 Ethernet network cable standard and offers the cost-effective solution for indoor Gigabit Ethernet data center applications, supporting up to 1000Mbps and 550MHz within 100 meters of cable. Fully PoE compatible and backwards compatible with Cat5e. All patch cords shall be compatible with both T568B wire scheme and passed Fluke Channel Test. Stranded copper patch cable can be used with a longer flex-life. Tested and verified to meet Cat6 component requirements for ANSI/TIA-568.2-D and ISO/IEC 11801 standards. The cable supports PoE to save you the expense and effort of powering PoE devices individually. You can also install PoE devices in locations distant from power outlets, such as high on walls, ceilings or poles. Variety of cable colors and lengths to meet individual requirements and system flexibility.
Cat6 UTP Patch Cable – 24AWG PVC CM
This Cat6 UTP Patch Cable is 24AWG PVC CM. Select the configuration that matches your installation and the specifications below.
Available options: Length: 0.5M, 10M, 15M, 1M, 2M, 3M, 5M; Color: black, blue.
Cat6 Snagless Unshielded (UTP) Ethernet Network Patch Cable, 24AWG, 1000Base-T
Specifications
Cable Type
Cat6 Snagless
Shielding Type
Unshielded (UTP)
Cable Jacket
PVC CM (Round)
Length
0.5m (Including Plugs)
Conductor Material
>99.95% Oxygen-free Copper
Conductor Type
Stranded
Plug Housing Material
Polycarbonate
Twisted Pairs
4
Data Rate Support
1000Base-T and Maximum to 10GBase-T
Maximum (Tested) Frequency
550MHz
Gauge (AWG)
24 (7/0.20mm)
Cable Outer Diameter (mm)
6.1 ± 0.4
PoE Compatibility
PoE/PoE+/PoE++
Connectors
RJ45 (Male)
Wire Scheme
T568B, Straight
Standard
ISO/IEC 11801, ANSI/TIA-568.2-D
Plug Type
8 Position
Support FSWireNet
No
관련 제품
90도 Cat6 26AWG 스내그리스 비차폐(U/UTP) PVC CM 이더넷 네트워크 패치 케이블, RJ45 직각 UP 수 - RJ45 수 - Cablefam
90도 Cat6 26AWG 스내그리스 비차폐(U/UTP) PVC CM 이더넷 네트워크 패치 케이블, RJ45 직각 UP 수 - RJ45 수 - Cablefam
Cat5e/Cat6/Cat6a RJ45 툴리스 모듈러 플러그, 23~26AWG 연선 또는 단선 케이블용 차폐 네트워크 커넥터 (10개입)
Cat5e/Cat6/Cat6a RJ45 툴프리 모듈러 플러그, 23~26AWG 연선 또는 단선 케이블용 비차폐 네트워크 커넥터 (10개입)
Cat6 23AWG 스나그리스 비차폐(U/UTP) LSZH 이더넷 네트워크 패치 케이블
Cat5e 이더넷 케이블
Cat6 이더넷 케이블
Cat6a 이더넷 케이블
Cat8 케이블
벌크 이더넷 케이블
커넥터 및 잭
케이블 정리
네트워크 도구 및 테스터
OS2 싱글모드 심플렉스
OS2 싱글모드 듀플렉스
OM3 멀티모드 파이버
OM4 멀티모드
OM2 멀티모드
OM5 멀티모드
MTP/MPO 케이블
패치 케이블 맞춤
광섬유 부품
청소용품 및 도구
DisplayPort 케이블
미니 디스플레이포트 케이블
HDMI 케이블
HDMI 미니/마이크로 케이블
DVI 케이블
VGA 케이블
오디오 케이블
썬더볼트 케이블
USB-C 케이블
USB 3.0 케이블
전원 케이블
SATA 케이블
시리얼 케이블