Cat6a network patch cable supports up to 10GBase-T and 550MHz within 100 meters of cable. And it is fully backward compatible with all the previous categories. The FS cat6a patch cables conductor apply Pure Bare Copper with high electrical conductivity and low signal transmission attenuation. The shielded patch cord provides superior alien crosstalk (AXT) suppression and protects critical data from electromagnetic and radio frequency interference (EMI/RFI). The sheath material is new environmentally friendly material PVC CM, which is durable, flame-retardant, resistant to bending. Stranded copper patch cable can be used with a longer flex-life. Tested and verified to meet Cat6a component requirements for ANSI/TIA-568.2-D and ISO/IEC 11801 standards. The cable supports PoE to save you the expense and effort of powering PoE devices individually. You can also install PoE devices in locations distant from power outlets, such as high on walls, ceilings or poles. Cat6a cable uses eight-core four-pair precision twisted pairing technology and passes the Fluke patch cord test. Compared with network cables that have passed channel testing, they have higher performance and are suitable for application environments with high performance requirements, such as medium and large data centers or brand data centers.
Cat6 26AWG Snagless Blindado (S/FTP) PVC CM Ethernet Network Patch Cable
Cat6a network patch cable supports up to 10GBase-T and 550MHz within 100 meters of cable.
US $4.95
- Utilizar materias primas de alta calidad
- Entrega rápida por defecto DHL o Fedex
- 60 días de devolución y cambio sin preocupaciones
- Atención al cliente profesional
Cat6a Snagless Shielded (SFTP) Ethernet Network Patch Cable, 26AWG, 550MHz, 10GBase-T
Specifications
Cable Type
Cat6a Snagless
Shielding Type
Shielded (SFTP)
Cable Jacket
PVC CM (Round)
Length
0.5m (Including Plugs)
Conductor Material
>99.95% Oxygen-free Copper
Conductor Type
Stranded
Data Rate Support
10GBase-T
Maximum (Tested) Frequency
550MHz
Gauge (AWG)
26 (7/0.16mm)
Cable Outer Diameter (mm)
6.2 ± 0.3
Max Transmission Distance
100m
Twisted Pairs
4 Pairs
Wire Scheme
T568B, Straight
Standard
ISO/IEC 11801, ANSI/TIA-568.2-D
Plug Type
8 Position
Support FSWireNet
No
Operating Temperature
-20 to +75°C (-4 to 167°F)
Installation Temperature
-10 to +50°C (14 to 122°F)
Productos relacionados
Cable de conexión de red Ethernet de PVC sin blindaje (U/UTP) sin hilos Cat5e de 10 m, negro
2m Cat5e Snagless Unshielded(U/UTP)LSZH Ethernet Network Patch Cable, Negro
90 grados Cat6 26AWG Snagless sin blindaje (U/UTP) PVC CM Ethernet Cable de conexión de red, RJ45 ángulo recto UP macho a macho RJ45
90 grados Cat6 26AWG Snagless sin blindaje (U/UTP) PVC CM Ethernet Cable de conexión de red, RJ45 ángulo recto UP macho a macho RJ45
Cable USB-A a USB-B USB 3.0 (5Gbps) activo - M/M - 5m/10m - TAA
Cables Cat5e
Cables Cat6
Cables Cat6a
Cables Cat8
Cables Ethernet a granel
Conectores y tomas
OS2 Monomodo Simplex
OS2 monomodo dúplex
OM5 multimodo
OM4 multimodo
OM3 multimodo
OM2 multimodo
Cables MTP/MPO
Conectividad de fibra óptica
Cables DisplayPort
Cables Mini DisplayPort
Cables HDMI
Cables HDMI Mini/Micro
Cables DVI
Cables VGA
Cables de audio
Cables Thunderbolt
Cables USB-C
Cables USB 3.0
Cables de alimentación
Cables SATA
Cables serie




